Dual Plate Check Valve Manufacturers
API 594 dual plate check valves are compact, lightweight, and fast-acting non-return valves designed to prevent reverse flow in industrial piping systems. The wafer-type configuration is installed between pipe flanges, making it an excellent choice where installation space, valve weight, and connection efficiency are important.
Unlike conventional swing check valves, a dual plate check valve uses two spring-loaded plates mounted on a central hinge mechanism. When the medium flows in the correct direction, the plates open. When forward flow decreases or reverses, the springs assist the plates in returning toward the closed position, helping reduce reverse flow and water hammer.
BOPIN Valve supplies API 594 STAINLESS STEEL RETAINERLESS WAFER TYPE DUAL PLATE CHECK VALVES in various sizes, pressure classes, body materials, trim combinations, and sealing configurations. They can be customized for water, steam, oil, gas, chemical, petrochemical, power-generation, and other industrial applications.

1. What Is an API 594 Dual Plate Check Valve?
An API 594 dual plate check valve is a non-return valve designed to permit flow in one direction while preventing flow in the opposite direction.
The valve contains two semicircular plates rather than one large disc. These plates are mounted on a hinge mechanism and are normally assisted by springs.
The basic operating principle is:
Forward flow → plates open → medium passes through
Flow decreases → springs help close plates → reverse flow is restricted
Reverse pressure → plates close against seats → backflow is prevented
The dual-plate design can provide a shorter closure stroke and lower moving mass compared with some conventional swing check valves. This makes it suitable for applications where rapid response and compact dimensions are important.
The wafer design is installed between two pipeline flanges. Unlike a flanged-end check valve, the wafer valve itself does not normally have integral flanges extending from the body.
2. API 594 Standards
API 594 is the primary standard associated with many dual plate and wafer check valve designs.
Depending on the project, additional standards may apply.
API 594
API 594 covers check valves and includes requirements related to:
- Design
- Pressure-temperature ratings
- Materials
- Dimensions
- Testing
- Marking
- Face-to-face dimensions
- Applicable connection configurations
API 598
API 598 is commonly referenced for valve inspection and pressure testing. Typical tests can include shell and closure testing according to the applicable requirements.
ASME B16.34
ASME B16.34 provides requirements for valves with respect to pressure-temperature ratings, materials, dimensions, and other design considerations.
ASME B16.5
For piping systems using ASME B16.5 flanges, the valve's dimensions and installation should be compatible with the specified flange arrangement.
ASME B16.47
For larger pipeline flange systems, ASME B16.47 may be applicable depending on the project design.
EN Standards
For projects designed according to European standards, relevant EN requirements may be specified for valve dimensions, pressure classes, flanges, and testing.
The exact standard combination should always be confirmed with the project specification and customer's technical requirements.
3. Wafer-Type Design
The wafer body is one of the most important features of an API 594 dual plate check valve.
The valve is positioned between two pipe flanges and secured by the flange bolts.
Advantages of the Wafer Design
Compact structure: The valve requires relatively little installation space.
Low weight: The absence of large integral flanges can reduce valve weight.
Easy installation: The valve can be positioned between existing pipeline flanges.
Cost efficiency: The compact design can reduce material consumption and associated installation costs.
Suitable for limited space: The short face-to-face dimension is useful in compact piping layouts.
However, correct flange alignment and bolt installation remain important. The valve should never be used to compensate for incorrectly aligned piping.
4. Main Features of API 594 Dual Plate Check Valves
Dual Plate Construction
The two independent plates divide the flow area into two sections. Their relatively small mass allows rapid movement during changes in flow.
Spring-Assisted Closing
Springs help return the plates toward the closed position when flow decreases.
This can improve the valve's response to flow reversal and help reduce the potential for severe reverse-flow events.
Low Pressure Drop
The internal flow path can provide relatively low resistance when the valve is correctly sized and operating under appropriate flow conditions.
Actual pressure loss depends on valve size, flow rate, medium, pressure, plate configuration, and internal geometry.
Reduced Water Hammer Potential
Fast-closing dual plate check valves can help reduce the magnitude of reverse-flow effects compared with some slower-closing check valve arrangements.
However, water hammer is a system-level phenomenon. Valve selection alone cannot guarantee elimination of water hammer.
Metal or Soft Seating
Depending on the application, the valve can be supplied with:
- Metal seats
- PTFE seats
- Reinforced PTFE
- Other suitable elastomeric or engineered sealing materials
Metal-seated versions are commonly preferred for high-temperature and severe-service applications.
Compact and Lightweight
The wafer configuration offers significant space-saving advantages compared with many conventional flanged check valves.
No External Actuator
A check valve is self-operating and normally does not require a handwheel, gearbox, or actuator.
5. Optional Materials
|
Material selection should be based on the medium, pressure, temperature, corrosion environment, and applicable standards. Carbon SteelASTM A216 WCB is commonly used for cast carbon-steel valve bodies in general industrial applications. It can be suitable for:
Stainless SteelCommon stainless-steel options include:
CF8M/316-type stainless steel is frequently selected when improved corrosion resistance is required. Duplex Stainless SteelDuplex materials can provide a combination of strength and corrosion resistance for demanding applications. Aluminum BronzeC95800 aluminum bronze can be considered for applications requiring suitable corrosion resistance, including certain seawater and marine environments. Special AlloysDepending on the application, special alloy materials can be evaluated for highly corrosive or high-temperature services. The plates, shafts, springs, seats, and other internal components can also be customized with suitable materials. |
![]() |
6. Applications
API 594 dual plate check valves are widely used in industrial piping systems.
Oil and Gas
They can be installed in:
- Hydrocarbon pipelines
- Gas systems
- Gathering systems
- Refinery process lines
- Pump discharge lines
Petrochemical Industry
Dual plate check valves can be used in process and utility piping where reliable backflow prevention is required.
Power Plants
Typical applications include:
- Cooling water
- Feedwater
- Steam-related auxiliary systems
- Condensate
- Boiler systems
- Pump discharge lines
Water Treatment
Wafer check valves are frequently used in:
- Water supply
- Wastewater systems
- Pump stations
- Filtration systems
- Desalination systems
Chemical Industry
Stainless steel and special-alloy versions can be selected for compatible chemical services.
Marine Applications
Appropriate corrosion-resistant materials can be selected for marine and seawater-related applications.
General Industrial Piping
They can be used wherever prevention of reverse flow is required and the operating conditions are compatible with the valve design.
7. Operation Manual
One advantage of a dual plate check valve is its automatic operation.
There is normally no handwheel or actuator.
Step 1: Check Installation
Before starting the system, verify:
- Valve size
- Flow direction
- Body markings
- Flange compatibility
- Pipe alignment
- Bolt installation
- Seat condition
- Valve cleanliness
The arrow on the valve body must correspond with the intended flow direction.
Step 2: Start the System Gradually
Introduce the medium gradually when possible.
As upstream pressure develops, the plates move away from the seats and allow flow through the valve.
Step 3: Normal Operation
During normal forward flow, the plates remain open according to the flow conditions.
The valve automatically responds to changes in differential pressure.
Step 4: Flow Reduction
When forward flow decreases, the springs assist the plates in moving toward the closed position.
Step 5: Reverse Flow
If downstream pressure becomes greater than upstream pressure, the plates move toward the seats and restrict reverse flow.
Step 6: Inspection
During service, monitor for:
- External leakage
- Abnormal vibration
- Unusual noise
- Excessive pressure loss
- Pipeline instability
If abnormal conditions occur, qualified personnel should inspect the valve and piping system.
8. Installation Precautions
Correct installation is essential for reliable check valve performance.
The pipeline should be properly supported before installing the valve. Excessive pipe stress should not be transferred to the valve.
Before installation:
- Clean the pipeline.
- Remove foreign material.
- Check flange alignment.
- Verify the flow direction.
- Inspect the valve.
- Confirm the correct gasket arrangement where applicable.
- Install flange bolts correctly.
- Tighten bolts progressively according to the applicable procedure.
Do not force the valve into a pipeline with poor alignment.
Also avoid installing a valve immediately downstream of a highly turbulent flow source unless the manufacturer's installation recommendations permit it. Pump outlets, elbows, reducers, and other fittings can create complex flow conditions that may influence check valve performance.
9. RFQ Requirements
For an accurate quotation, customers should provide detailed technical information.
A typical RFQ should include:
- Valve type: API 594 dual plate check valve
- Design: wafer type
- Nominal size: NPS/DN
- Pressure class
- Body material
- Plate material
- Seat material
- Spring material
- Shaft/hinge material
- Working medium
- Operating temperature
- Operating pressure
- Required flow rate
- Flange standard
- Face-to-face requirement
- Testing standard
- Inspection requirements
- Painting/coating requirements
- Marking requirements
- Quantity
- Packaging requirements
- Required documentation
- Delivery destination
For critical services, customers should also specify requirements for:
- PMI
- NDE
- Material certificates
- Third-party inspection
- Special testing
- NACE compliance
- Fire-safe requirements
- Fugitive-emission requirements
- Special coating systems
Providing complete information helps the manufacturer select the correct body, trim, seat, spring, and pressure class.
10. Why Choose BOPIN Dual Plate Check Valves?
BOPIN Valve focuses on supplying industrial valves for demanding process and piping applications. Our API 594 dual plate check valves can be configured according to customer requirements for different pressures, temperatures, media, materials, and connection standards.
Professional Manufacturing
BOPIN dual plate check valves are manufactured with attention to body machining, plate movement, spring installation, sealing surfaces, and dimensional accuracy.
Material Options
Customers can select carbon steel, stainless steel, duplex stainless steel, aluminum bronze, and other suitable materials according to the application.
Strict Testing
Valve inspection and pressure testing can be performed according to applicable standards and customer specifications. Testing can include shell and closure tests as required.
Customized Solutions
BOPIN can customize:
- Body materials
- Plate materials
- Seat materials
- Spring materials
- Pressure classes
- Sizes
- Marking
- Painting
- Packaging
- Documentation
OEM Service
For distributors and valve companies, BOPIN can provide OEM services, including customer markings and customized product configurations according to agreed specifications.
Export Packaging
After inspection, valves can be securely packed for international transportation. Packaging methods can be adapted according to valve size, quantity, transportation conditions, and customer requirements.